Edge FL – New 2023 Liquid-Cooled Industrial And Commercial Outdoor Cabinet
Narada liquid cooling battery cabinet consists of 8 battery modules,1 control box, and 1 liquid cooling unit. All wire connections are placed on the front side of the rack to allow for easy installation and maintenance.
Flexible Deployment
Modular structure, flexible combination, Plug-and-Play;
Higher energy design, less space usage; IP54 protection level with flexible application
Ultimate Integration
3S combination and control integration; CTP technology, all-in-one integration; AC&DC temperature differentiated management
High Level Of Safety
Multi-safety design & multi-protection assurance; Pre-alarm system, ensure system safety; Eligible for NFPA855, UL9540, UL9540A, GB standards
Ultra Long Life
High capacity and long battery cycle life, efficient active balancing system;
15 years of system-designed life
Intelligent Operation
Modular design, convenient
operation & flexible maintenance; Digital technology, remote collaboration & intelligent monitoring
Emergency Standby
AB configuration optional, off-grid and grid-connected flexible. Emergency green power supply, improve power quality
The Technology
Overall Specifications
Specifications for the Battery Cell
Content | Unit | Configuration |
Chemistry | – | LFP |
Type | – | Prismatic |
Size (WxDxH) | mm | 174.6*72.1*207.1 |
Weight | kg | 5.50±0.1 |
Related Capacity | Ah | 280 |
Related Energy | Wh | 896 |
Related Voltage | V | 3.2 |
Voltage Range | V | 2.8 to 3.6 |
Reference
Specifications for the Battery Module
Content | Unit | Configuration |
Configuration | – | 1P52S |
Main Components | – | 52 cells in series, module BMS |
Dimension (W×H×D) | mm | 760 × 237 × 1150 |
Weight | kg | 315±0.1 |
Related Capacity | Ah | 280 |
Related Energy | Wh | 46.59 |
Related Voltage | V | 166.4 |
Voltage Range | V | 145.6 to 187.2 |
Reference
Specifications for the Liquid Cooling Battery Cabinet
Content | Unit | Configuration |
Configuration | – | 1P416S |
Main Components | – | 8 modules, and 1 BAU |
Dimension (W×H×D) | mm | 1400×2250×1400 |
Related Capacity | Ah | 280 |
Related Energy | Wh | 372.7 |
Related Voltage | V | 1331.2 |
Voltage Range | V | 1164.8~1497.6 |
Maximum Power | – | 145.6 to 187.2 |
Fire System | – | Aerosol fire distinguish system and related fire alarm system |
Certification | – | IEC62619; UL1973; UL9540A |
Reference
Battery Management System
NARADA battery management system consists of 3 level BMS, including module level BMS (BMU), rack level BMS (BCU), system level BMS (BAU), the following drawing presents the communication topological of NARADA BMS.
Fig 1. BMS communication drawing
Cabinet Drawing Reference
Fig 2. Cabinet Drawing